Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; 1mΩ÷2kΩ; VAC: 0÷100V; IP54
Body dimensions: 203x148x78mm
Conform to the norm: CAT IV 100V; EN 61010
Standard equipment: ground earth stake (2pcs.); hard case; manufacturer's calibration certificate; test leads (3m, 10m, 15m); user's manual
Measuring instrument features: automatic power-off; function of automatic checking the resistance of the current and voltage loops
Type of meter: grounding resistance
Measurement: earth voltage; resistance (2-wire); resistance (3-wire)
Test voltage: 25V; 50V
AC voltage measuring range: 0...100V
Earthing resistance measuring range: 1mΩ...2kΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x8
AC voltage measuring accuracy: ±(2% + 2V)
Earthing resistance measuring accuracy: ±(2% + 3 digit)
Operating temperature: -15...55°C
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x8
IP rating: IP54
кількість в упаковці: 1 шт
товар відсутній
Відгуки про товар
Написати відгук
Технічний опис DET3TD MEGGER
Category: Earth Resistance Meter, Description: Meter: grounding resistance; LCD; 1mΩ÷2kΩ; VAC: 0÷100V; IP54, Body dimensions: 203x148x78mm, Conform to the norm: CAT IV 100V; EN 61010, Standard equipment: ground earth stake (2pcs.); hard case; manufacturer's calibration certificate; test leads (3m, 10m, 15m); user's manual, Measuring instrument features: automatic power-off; function of automatic checking the resistance of the current and voltage loops, Type of meter: grounding resistance, Measurement: earth voltage; resistance (2-wire); resistance (3-wire), Test voltage: 25V; 50V, AC voltage measuring range: 0...100V, Earthing resistance measuring range: 1mΩ...2kΩ, Battery/ rechargeable battery: battery LR6 AA 1,5V x8, AC voltage measuring accuracy: ±(2% + 2V), Earthing resistance measuring accuracy: ±(2% + 3 digit), Operating temperature: -15...55°C, Kind of display used: LCD, Power supply: battery LR6 AA 1,5V x8, IP rating: IP54, кількість в упаковці: 1 шт.
Інші пропозиції DET3TD
Фото | Назва | Виробник | Інформація |
Доступність |
Ціна без ПДВ |
---|---|---|---|---|---|
![]() |
DET3TD | Виробник : MEGGER |
![]() Description: Meter: grounding resistance; LCD; 1mΩ÷2kΩ; VAC: 0÷100V; IP54 Body dimensions: 203x148x78mm Conform to the norm: CAT IV 100V; EN 61010 Standard equipment: ground earth stake (2pcs.); hard case; manufacturer's calibration certificate; test leads (3m, 10m, 15m); user's manual Measuring instrument features: automatic power-off; function of automatic checking the resistance of the current and voltage loops Type of meter: grounding resistance Measurement: earth voltage; resistance (2-wire); resistance (3-wire) Test voltage: 25V; 50V AC voltage measuring range: 0...100V Earthing resistance measuring range: 1mΩ...2kΩ Battery/ rechargeable battery: battery LR6 AA 1,5V x8 AC voltage measuring accuracy: ±(2% + 2V) Earthing resistance measuring accuracy: ±(2% + 3 digit) Operating temperature: -15...55°C Kind of display used: LCD Power supply: battery LR6 AA 1,5V x8 IP rating: IP54 |
товар відсутній |