Продукція > C.A
Назва | Виробник | Інформація | Доступність | Ціна без ПДВ | ||||
---|---|---|---|---|---|---|---|---|
C.A 1110 | CHAUVIN ARNOUX | CA-1110 Luxmeters | на замовлення 5 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 1246 | CHAUVIN ARNOUX | CA-1246 Thermohygrometers | товару немає в наявності | |||||
C.A 1510 | CHAUVIN ARNOUX | CA-1510 Gas Meters and Loggers | товару немає в наявності | |||||
C.A 1631 | CHAUVIN ARNOUX | Category: Calibrators Description: Meter: calibrator; voltage,current; VDC: 0÷100mV,10V; I DC: 0÷24mA Kind of display used: LCD Dimensions: 205x97x45mm Illumination: yes Kind of calibrator: current; voltage Measurement: DC current; DC voltage DC current measuring range: 0...24mA DC voltage measuring range: 0...100mV; 10V Battery/ rechargeable battery: battery GR03 AAA 1,5V x6 Current source: 0...24mA Voltage source: 0...100mV; 0...20V DC voltage measuring accuracy: ±(0.02% + 3 digit) DC current measuring accuracy: ±(0.015% + 3 digit) Power supply: battery GR03 AAA 1,5V x6 Standard equipment: case; insulated crocodile clips; set of test leads with probes Measuring instrument features: 24V loop supply voltage Type of meter: calibrator | товару немає в наявності | |||||
C.A 1631 | CHAUVIN ARNOUX | Category: Calibrators Description: Meter: calibrator; voltage,current; VDC: 0÷100mV,10V; I DC: 0÷24mA Kind of display used: LCD Dimensions: 205x97x45mm Illumination: yes Kind of calibrator: current; voltage Measurement: DC current; DC voltage DC current measuring range: 0...24mA DC voltage measuring range: 0...100mV; 10V Battery/ rechargeable battery: battery GR03 AAA 1,5V x6 Current source: 0...24mA Voltage source: 0...100mV; 0...20V DC voltage measuring accuracy: ±(0.02% + 3 digit) DC current measuring accuracy: ±(0.015% + 3 digit) Power supply: battery GR03 AAA 1,5V x6 Standard equipment: case; insulated crocodile clips; set of test leads with probes Measuring instrument features: 24V loop supply voltage Type of meter: calibrator кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 1725 | CHAUVIN ARNOUX | CA-1725 Tachometers | товару немає в наявності | |||||
C.A 1727 | CHAUVIN ARNOUX | CA-1727 Tachometers | товару немає в наявності | |||||
C.A 1821 | CHAUVIN ARNOUX | CA-1821 Temperature and Humidity Loggers | товару немає в наявності | |||||
C.A 1822 | CHAUVIN ARNOUX | CA-1822 Temperature and Humidity Loggers | товару немає в наявності | |||||
C.A 1823 | CHAUVIN ARNOUX | CA-1823 Temperature and Humidity Loggers | товару немає в наявності | |||||
C.A 1866 | CHAUVIN ARNOUX | CA-1866 Pirometers | товару немає в наявності | |||||
C.A 1950 P01651901 | CHAUVIN ARNOUX | Category: Infrared Cameras - Others Description: Infrared camera; LCD 2,8"; 80x80; 9Hz; -20÷250°C; Focus: automatic Interface: Bluetooth; USB Resistance to: fall from 2m height Refresh rate: 9Hz Related items: CA-F407; CA-F607 Field of observation: 20° horizontal x 20° vertical Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation Type of meter: infrared camera Weight with battery: 700g Temperature measuring range: -20...250°C Emissivity value: 0,05...1 Three-dimensional resolution: 4.4mrad Focusing: automatic Camera resolution: 80x80 Thermal sensitivity (NETD): ≤0.08 @ 30°C Battery/ rechargeable battery: rechargeable battery Ni-MH x4 Software: included Temperature measurement accuracy: ±2%; ±2°C Kind of display used: LCD 2,8" Power supply: rechargeable battery Ni-MH x4 IP rating: IP54 Body dimensions: 225x125x83mm | товару немає в наявності | |||||
C.A 1950 P01651901 | CHAUVIN ARNOUX | Category: Infrared Cameras - Others Description: Infrared camera; LCD 2,8"; 80x80; 9Hz; -20÷250°C; Focus: automatic Interface: Bluetooth; USB Resistance to: fall from 2m height Refresh rate: 9Hz Related items: CA-F407; CA-F607 Field of observation: 20° horizontal x 20° vertical Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation Type of meter: infrared camera Weight with battery: 700g Temperature measuring range: -20...250°C Emissivity value: 0,05...1 Three-dimensional resolution: 4.4mrad Focusing: automatic Camera resolution: 80x80 Thermal sensitivity (NETD): ≤0.08 @ 30°C Battery/ rechargeable battery: rechargeable battery Ni-MH x4 Software: included Temperature measurement accuracy: ±2%; ±2°C Kind of display used: LCD 2,8" Power supply: rechargeable battery Ni-MH x4 IP rating: IP54 Body dimensions: 225x125x83mm кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 1954 P01651904 | CHAUVIN ARNOUX | Category: Infrared Cameras - Others Description: Infrared camera; LCD 2,8"; 160x120; 9Hz; -20÷250°C; IP54; 4.1mrad Interface: Bluetooth; USB Resistance to: fall from 2m height Refresh rate: 9Hz Related items: CA-F407; CA-F607 Field of observation: 38° horizontal x 28° vertical Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation Type of meter: infrared camera Weight with battery: 700g Temperature measuring range: -20...250°C Emissivity value: 0,05...1 Three-dimensional resolution: 4.1mrad Focusing: focus free Camera resolution: 160x120 Thermal sensitivity (NETD): ≤0.08 @ 30°C Battery/ rechargeable battery: rechargeable battery Ni-MH x4 Software: included Temperature measurement accuracy: ±2%; ±2°C Kind of display used: LCD 2,8" Power supply: rechargeable battery Ni-MH x4 IP rating: IP54 Body dimensions: 225x125x83mm | товару немає в наявності | |||||
C.A 1954 P01651904 | CHAUVIN ARNOUX | Category: Infrared Cameras - Others Description: Infrared camera; LCD 2,8"; 160x120; 9Hz; -20÷250°C; IP54; 4.1mrad Interface: Bluetooth; USB Resistance to: fall from 2m height Refresh rate: 9Hz Related items: CA-F407; CA-F607 Field of observation: 38° horizontal x 28° vertical Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation Type of meter: infrared camera Weight with battery: 700g Temperature measuring range: -20...250°C Emissivity value: 0,05...1 Three-dimensional resolution: 4.1mrad Focusing: focus free Camera resolution: 160x120 Thermal sensitivity (NETD): ≤0.08 @ 30°C Battery/ rechargeable battery: rechargeable battery Ni-MH x4 Software: included Temperature measurement accuracy: ±2%; ±2°C Kind of display used: LCD 2,8" Power supply: rechargeable battery Ni-MH x4 IP rating: IP54 Body dimensions: 225x125x83mm кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 5001 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; Features: blown fuse indicator; IP40 Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A DC current measuring accuracy: ±2.5% AC current measuring range: 5mA; 50mA; 0.5A; 5A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR6 AA 1,5V x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Body dimensions: 56x105x160mm Measuring instrument features: blown fuse indicator Standard equipment: test leads; test probes Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP40 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5001 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; Features: blown fuse indicator; IP40 Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A DC current measuring accuracy: ±2.5% AC current measuring range: 5mA; 50mA; 0.5A; 5A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR6 AA 1,5V x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Body dimensions: 56x105x160mm Measuring instrument features: blown fuse indicator Standard equipment: test leads; test probes Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP40 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5003 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A DC current measuring accuracy: ±2.5% AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Body dimensions: 56x105x160mm Measuring instrument features: automatic calibration; blown fuse indicator Standard equipment: test leads; test probes Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP53 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5003 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A DC current measuring accuracy: ±2.5% AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Body dimensions: 56x105x160mm Measuring instrument features: automatic calibration; blown fuse indicator Standard equipment: test leads; test probes Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP53 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5005 + MN89 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A DC current measuring accuracy: ±2.5% AC current measuring range: 3A; 10A; 30A; 100A; 240A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery 6F22 9V x1 Body dimensions: 56x105x160mm Measuring instrument features: automatic calibration; blown fuse indicator Standard equipment: CA-MN89 - current clamp; holster; test leads Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP53 | товару немає в наявності | |||||
C.A 5005 + MN89 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A DC current measuring accuracy: ±2.5% AC current measuring range: 3A; 10A; 30A; 100A; 240A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery 6F22 9V x1 Body dimensions: 56x105x160mm Measuring instrument features: automatic calibration; blown fuse indicator Standard equipment: CA-MN89 - current clamp; holster; test leads Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Producer guarantee (months): 36 IP rating: IP53 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 5011 | CHAUVIN ARNOUX | CA-5011 Analog Multimeters | товару немає в наявності | |||||
C.A 5231 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS Type of meter: digital multimeter Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 3x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Resistance measuring accuracy: ±(0.3%+4 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6LR61 9V x1 Standard equipment: test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance to: fall from 1m height Dimensions (W x H x D): 75x155x75mm Producer guarantee (months): 12 Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ) Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5231 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS Type of meter: digital multimeter Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 3x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Resistance measuring accuracy: ±(0.3%+4 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6LR61 9V x1 Standard equipment: test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance to: fall from 1m height Dimensions (W x H x D): 75x155x75mm Producer guarantee (months): 12 Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ) Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5231 KIT | CHAUVIN ARNOUX | CA-5231-KIT Portable digital multimeters | товару немає в наявності | |||||
C.A 5233 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 3x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz DC current measuring range: 6A; 10A; 15A < 60s DC current measuring accuracy: ±(1.5% + 3 digit) AC current measuring range: 6A; 10A; (15A <60s) AC current measuring accuracy: ±(2% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF Capacitance measuring accuracy: ±(3.5%+ 4 digit) Frequency measuring range: 10...3000Hz Frequency measuring accuracy: ±0.5% Temperature measurement accuracy: ±(2% + 5°C) Temperature measuring range (with K-type thermocouple): -20...760°C Resistance measuring accuracy: ±(0.3%+4 digit) Duty cycle factor: 0.1...99.9% Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6LR61 9V x1 Standard equipment: banana plug - K plug adapter; drop-like K-type probe; test leads Conform to the norm: CAT III 600V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 75x155x75mm Producer guarantee (months): 12 Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/REL function Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5233 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 3x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz DC current measuring range: 6A; 10A; 15A < 60s DC current measuring accuracy: ±(1.5% + 3 digit) AC current measuring range: 6A; 10A; (15A <60s) AC current measuring accuracy: ±(2% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF Capacitance measuring accuracy: ±(3.5%+ 4 digit) Frequency measuring range: 10...3000Hz Frequency measuring accuracy: ±0.5% Temperature measurement accuracy: ±(2% + 5°C) Temperature measuring range (with K-type thermocouple): -20...760°C Resistance measuring accuracy: ±(0.3%+4 digit) Duty cycle factor: 0.1...99.9% Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6LR61 9V x1 Standard equipment: banana plug - K plug adapter; drop-like K-type probe; test leads Conform to the norm: CAT III 600V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 75x155x75mm Producer guarantee (months): 12 Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/REL function Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5273 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 5x/s DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1.2% + 3 digit) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...3kHz DC current measuring range: 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6A; 10A AC current measuring accuracy: ±(1% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Temperature measurement accuracy: ±(0.5% + 2°C) Temperature measuring range (with K-type thermocouple): -59.6...1200°C Resistance measuring accuracy: ±(1%+2 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: drop-like K-type probe; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 90x190x45mm Producer guarantee (months): 36 Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; low input impedance function (LoZ); low-pass filter; MIN/MAX function Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5273 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 5x/s DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1.2% + 3 digit) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...3kHz DC current measuring range: 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6A; 10A AC current measuring accuracy: ±(1% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Temperature measurement accuracy: ±(0.5% + 2°C) Temperature measuring range (with K-type thermocouple): -59.6...1200°C Resistance measuring accuracy: ±(1%+2 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: drop-like K-type probe; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 90x190x45mm Producer guarantee (months): 36 Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; low input impedance function (LoZ); low-pass filter; MIN/MAX function Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5275 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance to: fall from 1m height Illumination: yes Standard equipment: case; MultiFIX mounting system; test leads; test probes Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX function; selection of AC or AC+DC measurement Type of meter: digital multimeter Test: diodes Continuity test: acoustic indication Sampling: 5x/s True effective value measurement: True RMS Bargraph: 61 segm. Producer guarantee (months): 36 Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 90x190x45mm Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Bandwidth for AC current measurements: 40Hz...1kHz DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Battery/ rechargeable battery: battery 6F22 9V x1 Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) AC current measuring accuracy: ±(1% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.8% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(1%+2 digit) Kind of display used: LCD Power supply: battery 6F22 9V x1 IP rating: IP54 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5275 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance to: fall from 1m height Illumination: yes Standard equipment: case; MultiFIX mounting system; test leads; test probes Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX function; selection of AC or AC+DC measurement Type of meter: digital multimeter Test: diodes Continuity test: acoustic indication Sampling: 5x/s True effective value measurement: True RMS Bargraph: 61 segm. Producer guarantee (months): 36 Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 90x190x45mm Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Bandwidth for AC current measurements: 40Hz...1kHz DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Battery/ rechargeable battery: battery 6F22 9V x1 Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) AC current measuring accuracy: ±(1% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.8% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(1%+2 digit) Kind of display used: LCD Power supply: battery 6F22 9V x1 IP rating: IP54 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5277 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 5x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Temperature measurement accuracy: ±(0.5% + 2°C) Temperature measuring range (with K-type thermocouple): -59.6...1200°C Resistance measuring accuracy: ±(1%+2 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: case; drop-like K-type probe; MultiFIX mounting system; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 90x190x45mm Producer guarantee (months): 36 Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5277 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 5x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Temperature measurement accuracy: ±(0.5% + 2°C) Temperature measuring range (with K-type thermocouple): -59.6...1200°C Resistance measuring accuracy: ±(1%+2 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: case; drop-like K-type probe; MultiFIX mounting system; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 90x190x45mm Producer guarantee (months): 36 Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5292 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement DC current measuring accuracy: ±(0.08% + 8 digit) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV Resistance measuring accuracy: ±(0.07%+8 digit) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Continuity test: acoustic indication Test: diodes Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Interface: USB IP rating: IP67 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Producer guarantee (months): 36 Temperature measuring range (with K-type thermocouple): -40...1200°C Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Illumination: yes Software: included Dimensions (W x H x D): 90x169x47.1mm Event memory: 10000 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 5292 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement DC current measuring accuracy: ±(0.08% + 8 digit) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV Resistance measuring accuracy: ±(0.07%+8 digit) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Continuity test: acoustic indication Test: diodes Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Interface: USB IP rating: IP67 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Producer guarantee (months): 36 Temperature measuring range (with K-type thermocouple): -40...1200°C Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Illumination: yes Software: included Dimensions (W x H x D): 90x169x47.1mm Event memory: 10000 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 5292-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 30000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes | товару немає в наявності | |||||
C.A 5292-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 30000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 5293 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 10000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 5293 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 10000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes | товару немає в наявності | |||||
C.A 5293-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.02% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 30000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes | товару немає в наявності | |||||
C.A 5293-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) Sampling: 5x/s DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.02% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Temperature measurement accuracy: ±0.1% Temperature measuring range (with K-type thermocouple): -40...1200°C Resistance measuring accuracy: ±(0.07%+8 digit) Test: diodes Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Producer guarantee (months): 36 Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Event memory: 30000 Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6113 | CHAUVIN ARNOUX | CA-6113 Multimeters for Electrical Installations | товару немає в наявності | |||||
C.A 6116N | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53 Type of meter: appliance meter Kind of display used: colour; LCD 5,7" Display resolution: 320x240 Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop Earthing resistance measuring accuracy: ±(2% + 2 digit) Loop impedance measuring accuracy: ±(5% + 2 digit) Continuity test: acoustic indication; optical indication Interface: USB Test voltage: 50V; 100V; 250V; 500V; 1kV Measuring instrument features: long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable Optional equipment: CA-C177A; CA-MN77 Power supply: rechargeable battery Li-Ion 10,8V x1 Body dimensions: 280x190x128mm Weight with battery: 2.2kg IP rating: IP53 Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: included RCD test: AC, A and F-type RCDs; general purpose Insulation resistance measuring ranges: 0.01MΩ...2GΩ Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ Illumination: yes Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6116N | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53 Type of meter: appliance meter Kind of display used: colour; LCD 5,7" Display resolution: 320x240 Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop Earthing resistance measuring accuracy: ±(2% + 2 digit) Loop impedance measuring accuracy: ±(5% + 2 digit) Continuity test: acoustic indication; optical indication Interface: USB Test voltage: 50V; 100V; 250V; 500V; 1kV Measuring instrument features: long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable Optional equipment: CA-C177A; CA-MN77 Power supply: rechargeable battery Li-Ion 10,8V x1 Body dimensions: 280x190x128mm Weight with battery: 2.2kg IP rating: IP53 Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: included RCD test: AC, A and F-type RCDs; general purpose Insulation resistance measuring ranges: 0.01MΩ...2GΩ Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ Illumination: yes Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6117 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53 Type of meter: appliance meter Interface: USB Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop Kind of display used: colour; LCD 5,7" Display resolution: 320x240 Continuity test: acoustic indication; optical indication IP rating: IP53 Body dimensions: 280x190x128mm Weight with battery: 2.2kg Power supply: rechargeable battery Li-Ion 10,8V x1 Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable Optional equipment: CA-C177A; CA-MN77 Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1 Measuring instrument features: built-in fuse table; long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: included Insulation resistance measuring ranges: 0.01MΩ...2GΩ Illumination: yes Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω RCD test: AC, B, B+, EV, A and F-type RCDs; general purpose Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ Loop impedance measuring accuracy: ±(5% + 2 digit) Earthing resistance measuring accuracy: ±(2% + 2 digit) кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6117 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53 Type of meter: appliance meter Interface: USB Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop Kind of display used: colour; LCD 5,7" Display resolution: 320x240 Continuity test: acoustic indication; optical indication IP rating: IP53 Body dimensions: 280x190x128mm Weight with battery: 2.2kg Power supply: rechargeable battery Li-Ion 10,8V x1 Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable Optional equipment: CA-C177A; CA-MN77 Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1 Measuring instrument features: built-in fuse table; long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: included Insulation resistance measuring ranges: 0.01MΩ...2GΩ Illumination: yes Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω RCD test: AC, B, B+, EV, A and F-type RCDs; general purpose Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ Loop impedance measuring accuracy: ±(5% + 2 digit) Earthing resistance measuring accuracy: ±(2% + 2 digit) | товару немає в наявності | |||||
C.A 6131 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 0÷800V; ±(1%+2digit); IP54 Type of meter: appliance meter Kind of display used: LCD Measurement: AC voltage; continuity; insulation resistance; phase sequence; RCD tripping time; resistance Continuity test: <10Ω AC voltage measuring range: 0...800V AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 1...10Ω; 100kΩ Power supply: battery LR6 AA 1,5V x6 IP rating: IP54 Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Dimensions: 223x126x70mm Measuring instrument features: Pass/Fail function Standard equipment: 3 crocodile clips; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Measurement memory: 2970 Illumination: yes Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Bargraph: yes RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Loop impedance measuring range: 100mΩ...1Ω; 400Ω кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6131 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 0÷800V; ±(1%+2digit); IP54 Type of meter: appliance meter Kind of display used: LCD Measurement: AC voltage; continuity; insulation resistance; phase sequence; RCD tripping time; resistance Continuity test: <10Ω AC voltage measuring range: 0...800V AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 1...10Ω; 100kΩ Power supply: battery LR6 AA 1,5V x6 IP rating: IP54 Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Dimensions: 223x126x70mm Measuring instrument features: Pass/Fail function Standard equipment: 3 crocodile clips; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Measurement memory: 2970 Illumination: yes Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Bargraph: yes RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Loop impedance measuring range: 100mΩ...1Ω; 400Ω | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6133 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Illumination: yes Measurement memory: 2970 Dimensions: 223x126x70mm Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Type of meter: appliance meter Continuity test: <10Ω RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Bargraph: yes Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Resistance measuring range: 1...10Ω; 100kΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω AC voltage measuring range: 2...550V Frequency measuring range: 30...1000Hz Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Software: dedicated mobile app Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Kind of display used: LCD Power supply: rechargeable battery Ni-MH AA x6 IP rating: IP54 Interface: Bluetooth кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6133 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Illumination: yes Measurement memory: 2970 Dimensions: 223x126x70mm Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Type of meter: appliance meter Continuity test: <10Ω RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Bargraph: yes Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Resistance measuring range: 1...10Ω; 100kΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω AC voltage measuring range: 2...550V Frequency measuring range: 30...1000Hz Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Software: dedicated mobile app Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Kind of display used: LCD Power supply: rechargeable battery Ni-MH AA x6 IP rating: IP54 Interface: Bluetooth | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6133 LAUNCH KIT | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth IP rating: IP54 Illumination: yes Measurement memory: 2970 Dimensions: 223x126x70mm Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Type of meter: appliance meter Continuity test: <10Ω RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Bargraph: yes Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Resistance measuring range: 1...10Ω; 100kΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω AC voltage measuring range: 2...550V Frequency measuring range: 30...1000Hz Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Software: dedicated mobile app Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Kind of display used: LCD Power supply: rechargeable battery Ni-MH AA x6 Interface: Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6133 LAUNCH KIT | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth IP rating: IP54 Illumination: yes Measurement memory: 2970 Dimensions: 223x126x70mm Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Type of meter: appliance meter Continuity test: <10Ω RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Bargraph: yes Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Resistance measuring range: 1...10Ω; 100kΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω AC voltage measuring range: 2...550V Frequency measuring range: 30...1000Hz Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Software: dedicated mobile app Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Kind of display used: LCD Power supply: rechargeable battery Ni-MH AA x6 Interface: Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6165 | CHAUVIN ARNOUX | Category: Electrical Safety Testers Description: Safety analyzer; 0÷20MΩ,100MΩ; Resolution: 480x272; 100÷240VAC Type of meter: safety analyzer Interface: Bluetooth; RS232 Kind of display used: LCD TFT Dimensions: 435x292x155mm Standard equipment: carrying case; crocodile clips; EURO mains power cable; manual (CD); probe; RS232 cable; test leads; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Display resolution: 480x272 Software: dedicated mobile app Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance IP rating: IP40 Supply voltage: 100...240V AC RCD test: 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA ; general purpose Test voltage: 50V; 100V; 250V; 500V; 1kV Insulation resistance measuring ranges: 0...20MΩ; 100MΩ Measurement memory: 6000 | товару немає в наявності | |||||
C.A 6165 | CHAUVIN ARNOUX | Category: Electrical Safety Testers Description: Safety analyzer; 0÷20MΩ,100MΩ; Resolution: 480x272; 100÷240VAC Type of meter: safety analyzer Interface: Bluetooth; RS232 Kind of display used: LCD TFT Dimensions: 435x292x155mm Standard equipment: carrying case; crocodile clips; EURO mains power cable; manual (CD); probe; RS232 cable; test leads; USB cable Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function Display resolution: 480x272 Software: dedicated mobile app Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance IP rating: IP40 Supply voltage: 100...240V AC RCD test: 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA ; general purpose Test voltage: 50V; 100V; 250V; 500V; 1kV Insulation resistance measuring ranges: 0...20MΩ; 100MΩ Measurement memory: 6000 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6240 | CHAUVIN ARNOUX | CA-6240 Miliohmmeters | товару немає в наявності | |||||
C.A 6255 | CHAUVIN ARNOUX | Category: Miliohmmeters Description: Milli-ohm meter; LCD; R range: 1uΩ÷2.5kΩ; Interface: RS232 Kind of display used: LCD Power supply: rechargeable battery Ni-MH x1 Interface: RS232 Measurement memory: 150 Dimensions: 270x250x180mm Standard equipment: Kelvin test leads; mains cable; RS232 cable; user's manual Measuring instrument features: automatic discharge after test; calculation of R at a reference temperature – Pt100 Ω probe; programmable alarm thresholds Type of meter: milli-ohm meter Resistance measuring range: 1µΩ...2.5kΩ Test current: 1mA @ 2.5kΩ; 10mA @ 250Ω; 100mA @ 25Ω; 1A @ 2500mΩ; 10A @ 5mΩ; 10A @ 25mΩ; 10A @ 250mΩ Software: included Resistance measuring accuracy: ±(0.05%+1µΩ) кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6255 | CHAUVIN ARNOUX | Category: Miliohmmeters Description: Milli-ohm meter; LCD; R range: 1uΩ÷2.5kΩ; Interface: RS232 Kind of display used: LCD Power supply: rechargeable battery Ni-MH x1 Interface: RS232 Measurement memory: 150 Dimensions: 270x250x180mm Standard equipment: Kelvin test leads; mains cable; RS232 cable; user's manual Measuring instrument features: automatic discharge after test; calculation of R at a reference temperature – Pt100 Ω probe; programmable alarm thresholds Type of meter: milli-ohm meter Resistance measuring range: 1µΩ...2.5kΩ Test current: 1mA @ 2.5kΩ; 10mA @ 250Ω; 100mA @ 25Ω; 1A @ 2500mΩ; 10A @ 5mΩ; 10A @ 25mΩ; 10A @ 250mΩ Software: included Resistance measuring accuracy: ±(0.05%+1µΩ) | товару немає в наявності | |||||
C.A 6416 | CHAUVIN ARNOUX | CA-6416 Earth Resistance Meter | товару немає в наявності | |||||
C.A 6417 | CHAUVIN ARNOUX | CA-6417 Clamp Meters - Others | товару немає в наявності | |||||
C.A 6418 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; Øcable: 32mm; OLED; IP40 Conform to the norm: CAT III 150V; CAT IV 100V; EN 61010 Body dimensions: 300x106x56mm Related items: CA-P01122301 Standard equipment: hard case; wristbands Measuring instrument features: AUTO HOLD; calibration function; manual HOLD function or automatic PRE-HOLD; measurements on wires and rectangular bars; programmable alarm thresholds: current, impedance Type of meter: grounding resistance Weight with battery: 1.2kg Max. diameter of measured cable: 32mm AC current measuring range: 10mA; 100mA; 300mA; 3A; 20A Earthing resistance measuring range: 10...100mΩ; 1Ω; 50Ω; 150Ω; 250Ω; 450Ω; 650Ω; 1.2kΩ Battery/ rechargeable battery: battery LR6 AA 1,5V x4 AC current measuring accuracy: ±(2% + 200µA) Earthing resistance measuring accuracy: ±(1.5% + 0.01Ω) IP rating: IP40 Power supply: battery LR6 AA 1,5V x4 Measurement memory: 300 Kind of display used: OLED | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6418 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; Øcable: 32mm; OLED; IP40 Conform to the norm: CAT III 150V; CAT IV 100V; EN 61010 Body dimensions: 300x106x56mm Related items: CA-P01122301 Standard equipment: hard case; wristbands Measuring instrument features: AUTO HOLD; calibration function; manual HOLD function or automatic PRE-HOLD; measurements on wires and rectangular bars; programmable alarm thresholds: current, impedance Type of meter: grounding resistance Weight with battery: 1.2kg Max. diameter of measured cable: 32mm AC current measuring range: 10mA; 100mA; 300mA; 3A; 20A Earthing resistance measuring range: 10...100mΩ; 1Ω; 50Ω; 150Ω; 250Ω; 450Ω; 650Ω; 1.2kΩ Battery/ rechargeable battery: battery LR6 AA 1,5V x4 AC current measuring accuracy: ±(2% + 200µA) Earthing resistance measuring accuracy: ±(1.5% + 0.01Ω) IP rating: IP40 Power supply: battery LR6 AA 1,5V x4 Measurement memory: 300 Kind of display used: OLED кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6422 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes Body dimensions: 223x126x70mm Conform to the norm: CAT IV 600V; EN 61010; EN 61557 Illumination: yes Standard equipment: user's manual Type of meter: grounding resistance Weight with battery: 1kg Earthing resistance measuring range: 0.05...50kΩ Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Earthing resistance measuring accuracy: ±(2% + 1 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x6 IP rating: IP65 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6422 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes Body dimensions: 223x126x70mm Conform to the norm: CAT IV 600V; EN 61010; EN 61557 Illumination: yes Standard equipment: user's manual Type of meter: grounding resistance Weight with battery: 1kg Earthing resistance measuring range: 0.05...50kΩ Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Earthing resistance measuring accuracy: ±(2% + 1 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x6 IP rating: IP65 | товару немає в наявності | |||||
C.A 6424 | CHAUVIN ARNOUX | CA-6424 Earth Resistance Meter | товару немає в наявності | |||||
C.A 6462 | CHAUVIN ARNOUX | CA-6462 Earth Resistance Meter | товару немає в наявності | |||||
C.A 6471 | CHAUVIN ARNOUX | CA-6471 Earth Resistance Meter | товару немає в наявності | |||||
C.A 6503 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; 250V,500V,1kV; IP54 Type of meter: insulation resistance Kind of display used: analogue Insulation resistance measuring accuracy: ±2.5% Test voltage: 250V; 500V; 1kV Conform to the norm: CAT II 600V; CAT III 300V; EN 61010 Standard equipment: 3 crocodile clips; carrying case; test leads ( 3pcs.); test probe x1 Power supply: built-in magneto IP rating: IP54 Weight without batteries: 1.06kg Body dimensions: 120x120x130mm Insulation resistance measuring ranges: 1...5000MΩ | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6503 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; 250V,500V,1kV; IP54 Type of meter: insulation resistance Kind of display used: analogue Insulation resistance measuring accuracy: ±2.5% Test voltage: 250V; 500V; 1kV Conform to the norm: CAT II 600V; CAT III 300V; EN 61010 Standard equipment: 3 crocodile clips; carrying case; test leads ( 3pcs.); test probe x1 Power supply: built-in magneto IP rating: IP54 Weight without batteries: 1.06kg Body dimensions: 120x120x130mm Insulation resistance measuring ranges: 1...5000MΩ кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6511 | CHAUVIN ARNOUX | CA-6511 Insulation Resistance Meters | товару немає в наявності | |||||
C.A 6513 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; R range: 0÷1kΩ Conform to the norm: CAT III 600V; EN 61010 Kind of display used: analogue Power supply: battery AA 1,5V x4 Body dimensions: 167x106x55mm Standard equipment: 1 crocodile clips; test leads ( 2pcs.); test probe x1; user's manual Type of meter: insulation resistance Continuity test: -10Ω...10Ω Measurement: AC voltage; insulation resistance; resistance Test voltage: 250V; 500V; 1kV Resistance measuring range: 0...1kΩ AC voltage measuring range: 0...600V Battery/ rechargeable battery: battery AA 1,5V x4 Insulation resistance measuring ranges: 1GΩ | товару немає в наявності | |||||
C.A 6513 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; R range: 0÷1kΩ Conform to the norm: CAT III 600V; EN 61010 Kind of display used: analogue Power supply: battery AA 1,5V x4 Body dimensions: 167x106x55mm Standard equipment: 1 crocodile clips; test leads ( 2pcs.); test probe x1; user's manual Type of meter: insulation resistance Continuity test: -10Ω...10Ω Measurement: AC voltage; insulation resistance; resistance Test voltage: 250V; 500V; 1kV Resistance measuring range: 0...1kΩ AC voltage measuring range: 0...600V Battery/ rechargeable battery: battery AA 1,5V x4 Insulation resistance measuring ranges: 1GΩ кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 6524 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Type of meter: insulation resistance Kind of display used: LCD Display parameters: (4000) Bargraph: yes DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) AC voltage measuring range: 300mV...400V; 700V Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Resistance measuring accuracy: ±(3%+2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Continuity test: <10Ω; <100Ω IP rating: IP54 Body dimensions: 211x108x60mm Weight without batteries: 850g Power supply: battery LR6 AA 1,5V x6 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Measurement memory: 300 Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ кількість в упаковці: 1 шт | на замовлення 3 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6524 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Type of meter: insulation resistance Kind of display used: LCD Display parameters: (4000) Bargraph: yes DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) AC voltage measuring range: 300mV...400V; 700V Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Resistance measuring accuracy: ±(3%+2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Continuity test: <10Ω; <100Ω IP rating: IP54 Body dimensions: 211x108x60mm Weight without batteries: 850g Power supply: battery LR6 AA 1,5V x6 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Measurement memory: 300 Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ | на замовлення 3 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6526 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Type of meter: insulation resistance Interface: Bluetooth Kind of display used: LCD Display parameters: (4000) Bargraph: yes DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) AC voltage measuring range: 300mV...400V; 700V Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Capacitance measuring range: 0.1...400nF; 4µF; 10µF Resistance measuring accuracy: ±(3%+2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Continuity test: <10Ω; <100Ω IP rating: IP54 Body dimensions: 211x108x60mm Weight without batteries: 850g Power supply: battery LR6 AA 1,5V x6 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: included Measurement memory: 1300 Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6526 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Type of meter: insulation resistance Interface: Bluetooth Kind of display used: LCD Display parameters: (4000) Bargraph: yes DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) AC voltage measuring range: 300mV...400V; 700V Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Capacitance measuring range: 0.1...400nF; 4µF; 10µF Resistance measuring accuracy: ±(3%+2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Continuity test: <10Ω; <100Ω IP rating: IP54 Body dimensions: 211x108x60mm Weight without batteries: 850g Power supply: battery LR6 AA 1,5V x6 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Test voltage: 50V; 100V; 250V; 500V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: included Measurement memory: 1300 Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6528 | CHAUVIN ARNOUX | CA-6528 Insulation Resistance Meters | товару немає в наявності | |||||
C.A 6545 | CHAUVIN ARNOUX | CA-6545 Insulation Resistance Meters | товару немає в наявності | |||||
C.A 6547 | CHAUVIN ARNOUX | CA-6547 Insulation Resistance Meters | товару немає в наявності | |||||
C.A 6608 | CHAUVIN ARNOUX | Category: Phase Sequence Indicators Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40 Type of tester: phase sequence Kind of display used: LCD Phase-to-phase voltage range for phase sequence indication: 40...850V AC Operating frequency: 15...400Hz IP rating: IP40 Body dimensions: 130x69x32mm Weight with battery: 130g Power supply: from tested wiring system Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7 Measurement: motor's rotation direction; phase sequence Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.) кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 6608 | CHAUVIN ARNOUX | Category: Phase Sequence Indicators Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40 Type of tester: phase sequence Kind of display used: LCD Phase-to-phase voltage range for phase sequence indication: 40...850V AC Operating frequency: 15...400Hz IP rating: IP40 Body dimensions: 130x69x32mm Weight with battery: 130g Power supply: from tested wiring system Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7 Measurement: motor's rotation direction; phase sequence Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.) | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6609 | CHAUVIN ARNOUX | CA-6609 Phase Sequence Indicators | товару немає в наявності | |||||
C.A 6681 | CHAUVIN ARNOUX | Category: Metals & cables detectors Description: Wire localizer; LCD; 12÷300VAC,12÷300VDC; Output signal: 125kHz Type of tester: wire localizer Kind of display used: LCD Detection: conductors at depth up to 2m (1-pole application); conductors at depth up to 0,5m (2-pole application); localisation of wire breaks; localises discontinuity in live conductors; localizes cable routes in ground; localizes given electric circuit protection; localizes routes of metal pipes for water and central heating systems; locating and tracing lines and outlets Detected voltage range: 12...300V AC; 12...300V DC Output signal: 125kHz Additional functions: torch Power supply: battery 6LR61 9V x7 Conform to the norm: CAT III 300V; EN 61010 Receiver dimensions: 241.5x78x38.5mm Transmitter dimensions: 190x89x42.5mm Measuring instrument features: detection of a metallic water supply and heating pipe; detection of faults in an in floor heating system; detection of the constricted (plugged) part of nonmetallic pipe; identification of supply circuit on the same floor; identyfication of pairs Standard equipment: a bayonet adapter B22; adapter for main socket; a earth spike; a screw adapter E27; case; crocodile clips; receiver; test leads; transmitter Battery/ rechargeable battery: battery 6LR61 9V x7 Bargraph: yes | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 6681 | CHAUVIN ARNOUX | Category: Metals & cables detectors Description: Wire localizer; LCD; 12÷300VAC,12÷300VDC; Output signal: 125kHz Type of tester: wire localizer Kind of display used: LCD Detection: conductors at depth up to 2m (1-pole application); conductors at depth up to 0,5m (2-pole application); localisation of wire breaks; localises discontinuity in live conductors; localizes cable routes in ground; localizes given electric circuit protection; localizes routes of metal pipes for water and central heating systems; locating and tracing lines and outlets Detected voltage range: 12...300V AC; 12...300V DC Output signal: 125kHz Additional functions: torch Power supply: battery 6LR61 9V x7 Conform to the norm: CAT III 300V; EN 61010 Receiver dimensions: 241.5x78x38.5mm Transmitter dimensions: 190x89x42.5mm Measuring instrument features: detection of a metallic water supply and heating pipe; detection of faults in an in floor heating system; detection of the constricted (plugged) part of nonmetallic pipe; identification of supply circuit on the same floor; identyfication of pairs Standard equipment: a bayonet adapter B22; adapter for main socket; a earth spike; a screw adapter E27; case; crocodile clips; receiver; test leads; transmitter Battery/ rechargeable battery: battery 6LR61 9V x7 Bargraph: yes кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 702 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: fixed test leads Additional functions: torch Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size Type of meter: digital multimeter Continuity test: acoustic indication; <60Ω Measurement: AC voltage; continuity; DC voltage; resistance Dimensions (W x H x D): 55x104x32.5mm Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V AC voltage measuring range: 2V; 20V; 200V; 600V Diode test: 1mA @1.5V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: (1999) DC voltage measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 8 digit) Resistance measuring accuracy: ±(0.08%+5 digit) Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 702 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: fixed test leads Additional functions: torch Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size Type of meter: digital multimeter Continuity test: acoustic indication; <60Ω Measurement: AC voltage; continuity; DC voltage; resistance Dimensions (W x H x D): 55x104x32.5mm Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V AC voltage measuring range: 2V; 20V; 200V; 600V Diode test: 1mA @1.5V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: (1999) DC voltage measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 8 digit) Resistance measuring accuracy: ±(0.08%+5 digit) Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 7028 | CHAUVIN ARNOUX | Category: LAN and Telephone Networks Testers Description: Tester: LAN wiring; LCD; 0÷40°C; 165x90x37mm; Illumin: yes Type of tester: LAN wiring Kind of display used: LCD Detection: discontinuities and short circuits in conductors; place of cable failure; reversed connection; screening continuity; split pairs Measurement: cable length; continuity Power supply: battery LR6 AA 1,5V x4 Operating temperature: 0...40°C Conform to the norm: EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-6; EN 61326-1; IEC 61010-1 Dimensions: 165x90x37mm Measuring instrument features: automatic power-off; identyfication of pairs; low battery indicator; testing and identifying up to 9 links; voltage presence indicator; wiring schemes: TIA 568A/B, USOC & ISDN Standard equipment: case; identifier; RJ45 connection cables Related items: CA-P01101994; CA-P01101995 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Test: cables FTP; cables SSTP; cables STP; cables UTP Illumination: yes | товару немає в наявності | |||||
C.A 7028 | CHAUVIN ARNOUX | Category: LAN and Telephone Networks Testers Description: Tester: LAN wiring; LCD; 0÷40°C; 165x90x37mm; Illumin: yes Type of tester: LAN wiring Kind of display used: LCD Detection: discontinuities and short circuits in conductors; place of cable failure; reversed connection; screening continuity; split pairs Measurement: cable length; continuity Power supply: battery LR6 AA 1,5V x4 Operating temperature: 0...40°C Conform to the norm: EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-6; EN 61326-1; IEC 61010-1 Dimensions: 165x90x37mm Measuring instrument features: automatic power-off; identyfication of pairs; low battery indicator; testing and identifying up to 9 links; voltage presence indicator; wiring schemes: TIA 568A/B, USOC & ISDN Standard equipment: case; identifier; RJ45 connection cables Related items: CA-P01101994; CA-P01101995 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Test: cables FTP; cables SSTP; cables STP; cables UTP Illumination: yes кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 703 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: fixed test leads Additional functions: torch Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size Type of meter: digital multimeter Continuity test: acoustic indication; <60Ω Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance Dimensions (W x H x D): 55x104x32.5mm AC current measuring range: 0.2mA; 2mA; 20mA; 200mA Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ DC current measuring range: 0.2mA; 2mA; 20mA; 200mA DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V AC voltage measuring range: 2V; 20V; 200V; 600V Diode test: 1mA @1.5V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: (1999) AC current measuring accuracy: ±(2.5% + 10 digit) DC voltage measuring accuracy: ±(0.5% + 3 digit) DC current measuring accuracy: ±(2% + 8 digit) AC voltage measuring accuracy: ±(1% + 8 digit) Resistance measuring accuracy: ±(0.08%+5 digit) Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 703 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: fixed test leads Additional functions: torch Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size Type of meter: digital multimeter Continuity test: acoustic indication; <60Ω Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance Dimensions (W x H x D): 55x104x32.5mm AC current measuring range: 0.2mA; 2mA; 20mA; 200mA Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ DC current measuring range: 0.2mA; 2mA; 20mA; 200mA DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V AC voltage measuring range: 2V; 20V; 200V; 600V Diode test: 1mA @1.5V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: (1999) AC current measuring accuracy: ±(2.5% + 10 digit) DC voltage measuring accuracy: ±(0.5% + 3 digit) DC current measuring accuracy: ±(2% + 8 digit) AC voltage measuring accuracy: ±(1% + 8 digit) Resistance measuring accuracy: ±(0.08%+5 digit) Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 732 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 195÷265VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 195...265V AC Additional functions: torch IP rating: IP40 Conform to the norm: CAT III 1000V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 732 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 195÷265VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 195...265V AC Additional functions: torch IP rating: IP40 Conform to the norm: CAT III 1000V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 742 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V Body dimensions: 163x64x40mm Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Standard equipment: carrying strap; test lead; test probe x1 Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Weight with battery: 210g Continuity test: acoustic indication; optical indication; <100Ω Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP65 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 742 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V Body dimensions: 163x64x40mm Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Standard equipment: carrying strap; test lead; test probe x1 Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Weight with battery: 210g Continuity test: acoustic indication; optical indication; <100Ω Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP65 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 742 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V Body dimensions: 163x64x40mm Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510 Type of tester: electrical Resistance to: fall from 2m height Standard equipment: carrying strap; IP2X test probes; test lead Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Weight with battery: 210g Continuity test: acoustic indication; optical indication; <100Ω Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP65 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 742 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V Body dimensions: 163x64x40mm Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510 Type of tester: electrical Resistance to: fall from 2m height Standard equipment: carrying strap; IP2X test probes; test lead Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Weight with battery: 210g Continuity test: acoustic indication; optical indication; <100Ω Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP65 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 745N | CHAUVIN ARNOUX | CA-745N Indicators, Voltage & Continuity Testers | на замовлення 3 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 751 | CHAUVIN ARNOUX | CA-751 Accessories - Others | товару немає в наявності | |||||
C.A 755 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC voltage; capacitance; continuity; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Dimensions (W x H x D): 180x52x45mm Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: test probes Resistance to: fall from 2m height IP rating: IP54 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 755 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC voltage; capacitance; continuity; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Dimensions (W x H x D): 180x52x45mm Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: test probes Resistance to: fall from 2m height IP rating: IP54 | товару немає в наявності | |||||
C.A 757 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) AC current measuring range: 500mA...30A; 300A AC current measuring accuracy: ±(3% + 5 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Dimensions (W x H x D): 180x52x45mm Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: probe MiniFlex; test probes; Velcro strap Resistance to: fall from 2m height IP rating: IP54 | товару немає в наявності | |||||
C.A 757 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) AC current measuring range: 500mA...30A; 300A AC current measuring accuracy: ±(3% + 5 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance Conform to the norm: CAT III 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Dimensions (W x H x D): 180x52x45mm Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: probe MiniFlex; test probes; Velcro strap Resistance to: fall from 2m height IP rating: IP54 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 762 | CHAUVIN ARNOUX | CA-762 Indicators, Voltage & Continuity Testers | товару немає в наявності | |||||
C.A 762 IP2X | CHAUVIN ARNOUX | CA-762-IP2X Indicators, Voltage & Continuity Testers | товару немає в наявності | |||||
C.A 771 | CHAUVIN ARNOUX | CA-771 Indicators, Voltage & Continuity Testers | товару немає в наявності | |||||
C.A 771 IP2X | CHAUVIN ARNOUX | CA-771-IP2X Indicators, Voltage & Continuity Testers | товару немає в наявності | |||||
C.A 773 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 Standard equipment: test probe x1; Velcro strap Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Kind of display used: LCD; LEDs Illumination: yes Resistance to: fall from 2m height Additional functions: torch Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Weight with battery: 350g Continuity test: acoustic indication; optical indication Phase-to-phase voltage range for phase sequence indication: 50...1000V AC RCD test: 30mA Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV IP rating: IP65 Body dimensions: 228x60x39mm Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1 Type of tester: electrical кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 773 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 Standard equipment: test probe x1; Velcro strap Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Kind of display used: LCD; LEDs Illumination: yes Resistance to: fall from 2m height Additional functions: torch Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Weight with battery: 350g Continuity test: acoustic indication; optical indication Phase-to-phase voltage range for phase sequence indication: 50...1000V AC RCD test: 30mA Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV IP rating: IP65 Body dimensions: 228x60x39mm Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1 Type of tester: electrical | товару немає в наявності | |||||
C.A 773 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 Type of tester: electrical Kind of display used: LCD; LEDs Phase-to-phase voltage range for phase sequence indication: 50...1000V AC AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV Continuity test: acoustic indication; optical indication Additional functions: 17 step speed regulation; torch IP rating: IP65 Resistance to: fall from 2m height Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1; NF C 18-510 Power supply: battery LR6 AA 1,5V x2 Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Standard equipment: IP2X test probes; Velcro strap Body dimensions: 228x60x39mm Weight with battery: 350g Battery/ rechargeable battery: battery LR6 AA 1,5V x2 RCD test: 30mA Illumination: yes кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 773 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 Type of tester: electrical Kind of display used: LCD; LEDs Phase-to-phase voltage range for phase sequence indication: 50...1000V AC AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV Continuity test: acoustic indication; optical indication Additional functions: 17 step speed regulation; torch IP rating: IP65 Resistance to: fall from 2m height Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1; NF C 18-510 Power supply: battery LR6 AA 1,5V x2 Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Standard equipment: IP2X test probes; Velcro strap Body dimensions: 228x60x39mm Weight with battery: 350g Battery/ rechargeable battery: battery LR6 AA 1,5V x2 RCD test: 30mA Illumination: yes | товару немає в наявності | |||||
C.A 8220 | CHAUVIN ARNOUX | Category: Power Quality Analyzers Description: Meter: power quality analyser; LCD; VAC: 6÷600V; True RMS; 40÷70Hz Conform to the norm: CAT III 600V; EN 61010 Illumination: yes Dimensions: 211x108x60mm Standard equipment: 2 crocodile clips; optical cable with USB; test leads ( 2pcs.); test probes Measuring instrument features: automatic power-off; automatic recognition various current detectors; datalogging; indicates phase sequence Type of meter: power quality analyser Weight with battery: 880g Optional equipment: CA-1711 techometr probe Continuity test: acoustic indication Pollution degree: 2 True effective value measurement: True RMS Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (with current clamps); Displacement Power Factor (DPF); frequency; harmonics; inrush current; power factor; reactive power; resistance; rpm velocity; temperature (option) AC voltage measuring range: 6...600V Frequency measuring range: 40...70Hz Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Power Analyser Transfer Kind of display used: LCD Power supply: battery LR6 AA 1,5V x6 IP rating: IP54 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 14-21 дні (днів) |
| ||||
C.A 8220 | CHAUVIN ARNOUX | Category: Power Quality Analyzers Description: Meter: power quality analyser; LCD; VAC: 6÷600V; True RMS; 40÷70Hz Conform to the norm: CAT III 600V; EN 61010 Illumination: yes Dimensions: 211x108x60mm Standard equipment: 2 crocodile clips; optical cable with USB; test leads ( 2pcs.); test probes Measuring instrument features: automatic power-off; automatic recognition various current detectors; datalogging; indicates phase sequence Type of meter: power quality analyser Weight with battery: 880g Optional equipment: CA-1711 techometr probe Continuity test: acoustic indication Pollution degree: 2 True effective value measurement: True RMS Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (with current clamps); Displacement Power Factor (DPF); frequency; harmonics; inrush current; power factor; reactive power; resistance; rpm velocity; temperature (option) AC voltage measuring range: 6...600V Frequency measuring range: 40...70Hz Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Power Analyser Transfer Kind of display used: LCD Power supply: battery LR6 AA 1,5V x6 IP rating: IP54 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
C.A 8335 MN93A | Chauvin Arnoux (Metrix) | на замовлення 1 шт: термін постачання 5 дні (днів) | ||||||
C.A 8336 | CHAUVIN ARNOUX | Category: Power Quality Analyzers Description: Meter: power quality analyser; colour,LCD TFT; Interface: USB Type of meter: power quality analyser Kind of display used: colour; LCD TFT Interface: USB Measuring instrument features: automatic recognition various current detectors; more than 450 recordable values with the required parameters and graphic displays; operation of several modes in parallel; possibility of viewing the data during a campaign; up to 40 alarms can be set simultaneously Standard equipment: 12-colour set to mark leads and inputs; aligator clip x5; carrying case; mains cable; manual (CD); screen protector preventing scratching (set); test leads ( 5pcs.); USB cable Power supply: rechargeable battery Ni-MH x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; IEC 61000-4-30 Producer guarantee (months): 36 Dimensions: 240x180x55mm Software: Power Analyser Transfer Display resolution: 320x240 Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (option); DC voltage; distorting power; energy; harmonics; inrush current; K factor for transformers; reactive power; short or long-term flicker Kind of network: three-phase Supply voltage: 100...240V AC IP rating: IP53 Number of inputs: 9 кількість в упаковці: 1 шт | товару немає в наявності | |||||
C.A 8336 | CHAUVIN ARNOUX | Category: Power Quality Analyzers Description: Meter: power quality analyser; colour,LCD TFT; Interface: USB Type of meter: power quality analyser Kind of display used: colour; LCD TFT Interface: USB Measuring instrument features: automatic recognition various current detectors; more than 450 recordable values with the required parameters and graphic displays; operation of several modes in parallel; possibility of viewing the data during a campaign; up to 40 alarms can be set simultaneously Standard equipment: 12-colour set to mark leads and inputs; aligator clip x5; carrying case; mains cable; manual (CD); screen protector preventing scratching (set); test leads ( 5pcs.); USB cable Power supply: rechargeable battery Ni-MH x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; IEC 61000-4-30 Producer guarantee (months): 36 Dimensions: 240x180x55mm Software: Power Analyser Transfer Display resolution: 320x240 Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (option); DC voltage; distorting power; energy; harmonics; inrush current; K factor for transformers; reactive power; short or long-term flicker Kind of network: three-phase Supply voltage: 100...240V AC IP rating: IP53 Number of inputs: 9 | товару немає в наявності | |||||
C.A 850 | CHAUVIN ARNOUX | CA-850 Manometers and Pressure Meters | товару немає в наявності |